BFZMP - LOCTITE GRADE C ANAEROBIC ADHESIVE, 250CC C, 8441
- MSDS: BFZMP
- Manufacturer: LOCTITE CORP
- Product Name: LOCTITE GRADE C ANAEROBIC ADHESIVE, 250CC C, 8441
- National Stock Number: 8030-00-964-7537
Product Identification
Product ID:LOCTITE GRADE C ANAEROBIC ADHESIVE, 250CC C, 8441
MSDS Date:05/24/1991
FSC:8030
NIIN:00-964-7537
MSDS Number: BFZMP
Responsible Party
NEWINGTON, CT 06111-1411
US
Emergency Phone: 203-278-1280
Info Phone: 203-278-1280
Preparer: STEPHEN REPETTO
Cage: 7K128
Contractor
Telephone: 860-571-5100
Cage: 05972
Ingredients
TRIBUTYL AMINE (APPROX 2.0%)
ORGANIC HYDROPEROXIDE
Fraction By Weight: <6%.
Hazards
Effects of Overexposure:MAY CAUSE DERMATITIS ON PROLONGED CONTACT IN
SENSITIVE INDIVIDUALS
First Aid
First Aid:SKIN & EYE:FLUS W/WATER. INGESTION:KEEP CALM & OBTAIN MEDICAL
ATTENTION. LD50 >10,000 M/KG-ACCORDING TO MFG.
Fire Fighting
Flash Point Method:TCC
Flash Point:>200F,>93C
Lower Limits:0.8%
Upper Limits:6.4%
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:IRRITATING ORGANIC VAPORS FORMED BY FIRE
OR THERMAL DECOMPOSITION.
Accidental Release
Spill Release Procedures:FLUSH W/SLVENTS, TAKING PRECAUTIONS FOR
POSSIBLE VAPORS & FIRE HAZARD OF SOLVENT USED. MIL-SPEC RECOMMENDS
WIPING OFF APILL W/A CLOTH MOISTENED W/WATER OR TRICHLOROETHYLENE.
Handling
Handling and Storage Precautions:STORE BELOW 110F, TO RETAIN SHELF LIFE
Other Precautions:AVOID PROLONGED SKIN CONTACT
Exposure Controls
Protective Gloves:RECOMMENDED
Eye Protection:RECOMMENDED
Supplemental Safety and Health
VAP PRESS: <5.0 AT 80F. SOLUBILITY IN WATER: LOW. ACCORDING TO MFR
TRIBUTYL AMINE IS AN IRRITANT. ORGANIC HYDROPEROXIDE IS AN OXIDIZER
Chemical Properties
HCC:N1
NRC/State Lic Num:NA
Boiling Pt:B.P. Text:>300F
Vapor Pres:<5 @ 80F
Spec Gravity:1.046
Solubility in Water:SLIGHT
Appearance and Odor:MILD ODOR;BLUE LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE W/FED, STATE & LOCAL
CODES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.